Fully Automatic Contact Angle Meter

Optical tensiometer

Automatic Contact Angle Meter QD500

Premium contact angle meter,high level of automation and accuracy for user-independent results.

Product Details​

The Fully Automated Series specializes in fully automated multi-functional measurement, featuring an automatic dispensing system and automatic liquid collection system. Utilizing an advanced multi-point programming control system, it enables one-button fully automated batch testing, seamlessly integrating with industrial assembly line operations. Through a highly integrated intelligent measurement solution, it significantly enhances high-throughput testing efficiency, effortlessly handles large-scale surface analysis demands, boosts production efficiency, and reduces labor costs.

 

What you can measure

  • Measure static contact angles
  • Automatic Drip System
  • Wetting process Analysis
  • Dynamic contact angle: Advancing angle, receding angle, hysteresis angle (liquid addition/subtraction method).
  • solid surface free energy, and its distribution.(Dispersion forces, polar forces, hydrogen bonding forces).
  • Surface tension
  • Wettability Analysis
  • Select any point within the region
  • Matrix-type multi-point testing, capable of measuring over 50 points at once
  • Automated sampling-shifting-dispensing-testing-cycling-data reporting

Measurements​

Sessile drop​

For static contact angle measurement of a liquid droplets

captive bubble​

static contact angle measurement of a gas bubble

wetted fiber
wetted fiber​

For static contact angle measurement with a fiber/rod

Surface Free Energy

Use for characterizing the wettability of materials

advancing angle
Advancing Angle​

For dynamic contact angle measurement

receding angle
Receding Angle​

For dynamic contact angle measurement

pendant drop
Pendant Drop​

For surface and interfacial tension

pendant drop
Reverse pendant drop

 For surface and interfacial tension

Real-time Spectrogram
Real-time Spectrogram

For curve analysis and comparison display

 

Wetting Envelopes

Wettability analysis for material surface

Real Droplet​

For testing non-axisymmetric contact angle

Specifications​

modelQD 500
nameFully Automatic Contact Angle Measuring Instrument/Surface Tension Tester
General Indicators
Angle range0°<θ<180°
precision0.1°
Baseline fittingAutomatic and manual
Test accuracy0.1°
Instrument size680mm(W)*380mm(L)* 600mm(H)
Fuselage materialAviation aluminum
weightAbout 25KG
Power SupplyAC100~240V 50/60HZ
Software operating system requirementsWindows 10(64-bit)
AccessoriesOptional accessories: Professional fiber fixtures, specialized films, and plant leaf fixtures for analyzing contact angle values on fibrous or uneven-surface samples.
Sample platform system
Left and right x movement200mm(Automatic)
Y-shift back and forth200mm(Automatic)
Z-move up and down30mm
Sample Stage Tilting SystemOptional: Manual tilt or electric tilt system
Sample stage dimensions130mm*150mm(customizable)
Maximum sample that can be placed200(W)*∞(L)*30(H)mm
Mode of transportationAutomatic(programmable)
Injection System
Needle Tube YZ Mobile40mm*30mm
Dropping control movement45mm
Liquid adding modeAutomatic(Recyclable, Programmable, Continuous Testing)
Dropping speed0.01-25ul/s
Dropping accuracy0.01ul
Pipetting methodAutomatic(programmable)
needle10 stainless steel needles (replaceable) of 0.5mm and 10 superhydrophobic needles (replaceable) of 0.25mm are standard.
Imaging system
cameraSONY imported high-speed industrial-grade chips from Japan (Onsemi exposure)
Lensindustrial Continuous Magnification Lens 0.7X-4.5X
Sensor type1/2.7 inch global scanning CMOS
focal distance±2.5mm adjustable
Image shooting methodSingle sheet, interval, continuous
Shooting interval time500-3600000ms
Video recording modeVideo recording, rebroadcasting and synthesis
Maximum shooting speed400frames /s
Service lifeMore than 20,000 h
Light source wavelength465nm
Light Source SystemIndustrial blue cold light source imported from the United States (effectively avoiding evaporation of droplets due to heat emitted by the light source)
Contact Angle Testing and Analysis
Measurement MethodSessile Drop(2/3)、Pendant Drop、Captive Drop、wetted fiber、Advancing Angle、Receding Angle、Surface Free Engery、real drop
Contact Angle Calculation MethodAutomatic fitting method (ms-level one-key automatic fitting, without manual error), three-point fitting, five-point fitting, automatic measurement (including Circle method/ Oblique Circle fitting, Ellipse method /Oblique Ellipse fitting), concave-convex surface measurement, B-Snake、B-Spline、Spline、Bipolynomial Method
Analytical MethodsCombining fully automated testing with manual testing
Dynamic contact angleAdvancing angle, receding angle, hysteresis angle.(Multiple pictures can be fitted in batches or videos can be fitted continuously to calculate Video analysis)
Rolling AngleOptional: Manual or Automatic Tilting Platform
Automatic Surface CorrectionConvex Surface, Surface Roughness Correction
Baseline fittingAutomatic and manual
Surface Free Energy Analysis
12Methods of Surface Energy AnalysisFowks method, OWRK method, Zisman method, EOS method, Acid-Base Theory method, Wu harmonic mean method and Extended Fowkes method and so on.
(37 kinds of liquid databases are pre-installed in the software, and the liquid performance parameters can be established by themselves) can be directly transferred for surface energy estimation, and the data in the liquid database can be added, deleted and modified by itself. Solid surface energy, dispersion force, polar force, hydrogen bonding force, van der Waals component, Lewis acid component, Lewis base component and so on can be obtained respectively.
Surface Tension Analysis
Measurement methodAutomatic fitting+manual fitting
Test Range0.01mN/m-2000mN/m
precision0.01mN/m
Calculation MethodSuspended Drop Method
Wettability Analysis
Wettability AnalysisOne-click automatic analysis of spreading coefficient, adhesion work, and adhesion tension
Report OutputAutomatically generated reports exportable in Excel, Word, PDF, and diagram formats.